Opened 10 years ago
Last modified 8 years ago
#43780 assigned defect
sane-backends Trace/BPT trap: 5 after port upgrade
Reported by: | leonfauster@… | Owned by: | macports-tickets@… |
---|---|---|---|
Priority: | Normal | Milestone: | |
Component: | ports | Version: | 2.2.1 |
Keywords: | Cc: | cooljeanius (Eric Gallager), tobypeterson | |
Port: | sane-backends, libusb-compat |
Description
sane-backends was working fine with this scanner "Canon CanoScan N1240U/LiDE30"
after upgrading all outdated ports i noticed the "Trace/BPT trap: 5" message.
$ port installed |grep -i -E 'sane|twain|gette|libusb' gettext @0.18.3.2_0+universal (active) libusb @1.0.17_0+universal libusb @1.0.18_0+universal (active) libusb-compat @0.1.4_0+universal libusb-compat @0.1.5_0+universal (active) p5.12-locale-gettext @1.50.0_7 (active) p5.16-locale-gettext @1.50.0_7 (active) sane-backends @1.0.22_4+universal (active) twain-sane @3.0_0 (active)
$ port version Version: 2.2.1
$ cat /opt/local/etc/sane.d/dll.conf | grep -v '#' plustek
$ scanimage -L device `plustek:libusb:020:001' is a Canon CanoScan N1240U/LiDE30 flatbed scanner Trace/BPT trap: 5 $ echo $? 133
$ SANE_DEBUG_DLL=111 scanimage -L [sanei_debug] Setting debug level of dll to 111. [dll] sane_init: SANE dll backend version 1.0.13 from sane-backends 1.0.22 [dll] sane_init/read_dlld: attempting to open directory `./dll.d' [dll] sane_init/read_dlld: attempting to open directory `/opt/local/etc/sane.d/dll.d' [dll] sane_init/read_dlld: opendir failed: No such file or directory [dll] sane_init/read_config: reading dll.conf [dll] add_backend: adding backend `plustek' [dll] sane_get_devices [dll] load: searching backend `plustek' in `/opt/local/lib/sane' [dll] load: trying to load `/opt/local/lib/sane/libsane-plustek.1.so' [dll] load: dlopen()ing `/opt/local/lib/sane/libsane-plustek.1.so' [dll] init: initializing backend `plustek' [dll] init: backend `plustek' is version 1.0.0 [dll] sane_get_devices: found 1 devices device `plustek:libusb:020:001' is a Canon CanoScan N1240U/LiDE30 flatbed scanner [dll] sane_exit: exiting [dll] sane_exit: calling backend `plustek's exit function Trace/BPT trap: 5
scanning works but
$ scanimage --resolution 300 --mode Color -l 0 --format tiff -x 215 -y 297 > tmp3.tif Killed: 9 $ echo $? 137
Change History (8)
comment:1 Changed 10 years ago by leonfauster@…
comment:2 Changed 10 years ago by leonfauster@…
$ sw_vers ProductName: Mac OS X ProductVersion: 10.8.5 BuildVersion: 12F45
comment:4 Changed 10 years ago by mf2k (Frank Schima)
Owner: | changed from macports-tickets@… to aguynamedryan+sane@… |
---|
In the future, please Cc the port maintainers (port info --maintainers sane-backends
).
comment:6 Changed 8 years ago by leonfauster@…
I have migrated my scan station to 10.11. (El Capitan) and the same behaviour persists. Fresh installed OS and macports and scanimage -L exits with non zero status. Downgrading libusb-compat @0.1.4 solved it.
comment:7 Changed 8 years ago by ryandesign (Ryan Carsten Schmidt)
Cc: | toby@… added; leonfauster@… removed |
---|---|
Port: | libusb-compat added |
Has duplicate #52240.
comment:8 Changed 8 years ago by mf2k (Frank Schima)
Owner: | changed from aguynamedryan+sane@… to macports-tickets@… |
---|---|
Status: | new → assigned |
See #52241.
Note: See
TracTickets for help on using
tickets.
activating the older compat lib helps to get expected behaviour